Handling methods for common problems in heat transfer oil furnaces:
1. Operate strictly according to the heating curve.
2. When the furnace is shut down, the hot oil circulation pump can be stopped when the oil temperature drops below 80 degrees Celsius.
3. Ensure that the heat transfer oil circulates well during high temperature conditions.
4. During normal operation, the heat transfer oil in the high tank maintains a high liquid level, and the heat transfer oil in the oil storage tank should be at a low liquid level.
5. The oil temperature should not exceed the allowable operating temperature of the heat transfer oil.
6. Do not put into use when the pressure difference is unstable.
7. Do not flush the furnace with water during emergency shutdown.
8. Different types of heat transfer oil should not be mixed.
9. The boiler room should be equipped with electrical and oil fire-fighting equipment.
10. The first heating rate must be based on the heating curve.
11. The vent of the oil storage tank should be connected to the safe area.