Monitoring function realized by the automatic control system of the plate sterilization machine

Monitoring function realized by the automatic control system of the plate sterilization machine

In the programmable controller of the plate sterilization machine, the output signals of each temperature zone are linked with the water pump, that is, the pneumatic diaphragm valve can perform automatic adjustment only when the water pump works and the relay is closed, otherwise the regulating valve will automatically close. In addition, for the sterilization constant temperature zone and the highest temperature zone, if a certain part of the production line fails, the bottle conveying mechanism stops working, and the system will automatically adjust the temperature setting value according to the length of the downtime to ensure the sterilization quality.

(1) Set the PU value to display the PU value reached by the material in the sterilizer in real time.

(2) Display the temperature set value and measured value of each temperature zone in real time. When the temperature is too high or too low, the alarm screen will pop up.

(3) Real-time display of the pressure value of the water pump in each temperature zone. When the pressure is insufficient, an alarm screen will pop up.

(4) Indicate the switching state of each regulating valve.

(5) Manually control the switching state of the regulating valve.

(6) Historical trend graph display.

(7) Select the PID operation by the upper computer or the lower computer.