How to solve the problem of air shower

How to solve the problem of air shower

Clicks: 4652 Release time: 2017/2/7

How to solve the problem of air shower
Everyone knows that industrial equipment will inevitably have some use problems in the operation of the project. It is a problem of its own operation, or the quality of the air shower room itself. The former can be negotiated with the air shower room manufacturer. The latter should be free of charge for the air shower room manufacturer. On-site maintenance and treatment, and find the cause of the relevant problems, but in the next time in the management of the air shower system to develop relevant measures to avoid duplicate product related issues; air shower room main fault problems are now organized as follows for your reference:
Enterprises that use the air shower room sometimes encounter problems in the air shower room. When the staff of the air shower room consumer manufacturer fails to go to the scene to deal with the problem in time, it is not possible to refer to the following common problems related to the air shower room, which may help you answer.
First, the power switch. Usually the air shower has four central units that can cut off the power:
1. The power switch of the outdoor shower box;
2. The control panel of the air shower indoor cabinet;
3. The air box on both sides of the air shower room (the power switch can prevent the power supply from being cut off in an emergency situation, effectively improving the personal safety of the staff). When the power indicator does not work, do not prevent re-checking the above four air shower room power supplies.
4 If the air shower is running, if it can be opened, the lock tongue is not completely inserted into the lock hole;
5 The air shower door presents self-locking or blowing without stopping, opening the door and entering the sensing area without blowing—that is, the program has been mishandled and disordered. Please turn off the main power and then press the program again to start normally.
Second, the air shower room fan reverse or the air shower room wind speed is very small, please be sure to check whether the 380V three-phase four-wire line can be reversed, the ordinary air shower room consumer manufacturers will have a special person's electrician to connect the line; Reversed the line source of the air shower chamber, the lighter will cause the air shower chamber fan to not work or the reverse air shower chamber wind speed to decrease, the heavy one will burn off the circuit board of the entire air shower chamber; as the air shower room manufacturer, we It is recommended that the wind shower room enterprises should not change the wiring lightly. If the consumption demand must be moved, please consult the air shower room manufacturer.
Third, when the air shower fan does not work. When the air shower is not working, *Check to see if the emergency switch of the outdoor shower box can be cut off. If it is cut off, press it with your hand and turn it to the right to release it.
Fourth, the air shower room does not blow, in addition to the above three points, it is also necessary to check whether the emergency stop button inside the air shower room can be pressed, such as the emergency stop button for the color, the air shower will not blow ; Press the emergency stop button again to work properly.
5. When the air shower room cannot automatically sense the air blow, please check the light sense system in the lower right corner of the air shower indoor box to see if the light sensor installation can be installed correctly. If the light sense is positive on both sides and the light sense is normal, it can be automatically sensed. Blowing.
6. When the air shower is used for a period of time, the wind speed is very low. Please check whether the initial and high-efficiency filters of the air shower are excessively dusty. If so, please change the filter. (Air filter room primary effect filter is changed once in normal 1-6 months, air shower room high efficiency filter is changed within 6-12 months)
After understanding the common problems of the above air shower room, the majority of friends must pay attention to the use of the air shower room in the future. If there is a problem after the warranty period, some air shower room manufacturers will find various reasons to shirk responsibility, resulting in additional losses for users.

[ print ] [ back to top ] [ close ]