Common problems and causes of the sealing machine

1. Problem: The tape cannot be cut.

the reason:

1 blade is not sharp enough;

2 The tip of the knife is blocked by the adhesive.

Solution: Replace the blade or cleaning blade.

2. Problem: There is a trailing tail after the tape is cut.

the reason:

1 blade is not sharp enough;

2 blocks on the knife seat;

3 The tension spring is too loose.

Solution: Check that the screws on the holder are too loose and lubricate them if necessary.

3. Problem: The tape is broken during the sealing process.

Cause: The blade extends too long.

Solution: Adjust the blade position.

4. Problem: The tape does not completely bond the box.

the reason:

1 main spring is too loose;

2 The adhesive deposited on the roller shaft does not work properly;

3 tape failed.

Solution: Tighten the main springs, lubricate these roller shafts, and replace the tape.

5. Problem: The box is stuck in the middle.

the reason:

The tape wheel adjustment nut is too tight;

The height of the box is adjusted unreasonably;

The active spring is too tight.

Solution: Loosen the tape wheel adjustment nut, re-adjust the height, and loosen the main spring.

Double Arm Electric Surgical Pendant

Lewin double arms medical pendants surgeon's pendant will support all medical equipment such as monitors,camera,power tools and video and etc,can position all the equipment conveniently adjacent to the surgical site. Medical pendants provide medical gas,electrical and data services.For the pendants, customer can customize arm length.All kinds of terminal such as medical gas, electricity and network are gathered on the control board. Some medical machines of certain weight can be placed in the board and drawer.